The 10 most common problems with a NuTone IM / IMA4406 Music Intercom System

NuTone introduced the IM4406 in 1996 and it replaced the very popular IMA4006. By 1996 everyone was ready for a new top-of-the-line model and NuTone hit a home run with the IM4406.

The IM4406 included a powerful 20 watt amplifier along with AM & FM radio, and for the first time, a single disc CD player was built into the master station. The IM4406 featured “hands-free-reply” intercom operation and remote music control from every station. Probably the only complaint I heard about the IM4406 was the additional cost over the IMA4006.

One concern was the size of the IM4406 because it was 1-1/2” taller than the IMA4006. NuTone learned back in the 1970's that homeowners don't like large master stations, but the additional size was necessary to accommodate the CD player.

There are 3 different variations of the 4406, however the models are labeled as if there were only 2 variations. The original IM4406 was produced from 1996 through about 2002, then the IMA4406 was put into production.

There are actually 2 variations of the IMA4406 and it seems that sometime around 2005 the electronics were updated without the benefit of model number change. This “3rd” model may have corresponded with the change of which factory manufactured the masters.

 

First I will focus on the original IM4406:

The IM4406 was and has been, a fairly trouble-free model since its introduction. There were the typical new model issues which were mainly CD related problems. Many of these “problems” were associated with the CD player getting contaminated with dirt and sheet rock dust during the construction of a new home. There was also some confusion with the types of CD's that the IM4406 could play.

The IM4406 could play all commercially purchased CD's without any problems, but if you remember back in those days people were just starting to “burn” CD's on their computers and the IM4406 had problems reading these homemade CD's. There was also a rumor that the IM4406 could play MP3 files that were burned on homemade CD's, which was not true.

Unfortunately, the CD player assembly for the original IM4406 is no longer available and there doesn't seem to be any reasonable repair option for the original player. The original CD player assembly was manufactured for NuTone by a vendor which made CD player assemblies for many different companies. As with all modern manufacturing, once the demand for the assemblies is gone, the vendor stops production of the units.

 

There are basically 2 problems that occur with the CD player:

 

  1. The motor that moves the lens (which reads the CD) will fail and the lens just stays in one spot. While this is a small part, it is not possible to purchase replacements from the original vendor.

  2. All CD players will eventually develop a problem with the laser that reads the information off the CD. The laser beam will become weaker and weaker over time and finally it will become so weak that the reflection off the CD is not strong enough to be read. Again, without an exact replacement from the original vendor, repairing this problem is not possible.

     

(The original IM4406 CD Player Assembly)

Since the use of CD's has diminished a lot since 1996, the best and most popular solution with our customers is to abandon the CD all together and add a miniature input jack to the side or bottom of the IM4406. This jack can be used for any MP3 player (iPod or iPad) or an external CD player. This jack can also be used to connect a satellite radio receiver (XM or Sirius).

 

Power Supply Failures: 

 

A new problem that seems to be developing with the original IM4406 is the failure of the power supply circuit on the Power / Amplifier circuit board. This should not be confused with the 2 low-voltage transformers (model 801T's) that are mounted in the IR105 Wall Housing. (Caution: The 801T transformers have built-in internal fuses, if the output of the transformers is shorted, it will blow the fuse and the transformer will go dead. The fuse is not replaceable and a new transformer will need to be purchased!!!)

The first sign of trouble with a failing power supply on most NuTone Intercom Systems is an increase in the background noise of the system. All NuTone Intercom systems had a certain amount of background noise which could be heard if you listened very carefully with your ear up against the speaker. This light “hissing” sound is called “white noise” and it's the sound an amplifier makes when it's turned on.

This background noise was eliminated with the introduction of a new intercom platform in 1994. All of the NuTone models produced from 1994 through 2008 were designed with a “stand-by” mode. When the intercom system was not in use (not listening to music or using the intercom) the amplifier will switch off and the system became silent, no more background noise.

Since the IM4406 has a “stand-by” mode, when the power supply begins to fail, a homeowner will not hear the increase of the background noise of the system. It's not that the increase isn't there, it's just that since the system is in “stand-by” you can't hear it.

The first symptom a homeowner may notice is a random “static” or “crackling” noise from the speakers even when the system is in stand-by. There may also be a loss of volume with the music and door chime. Most of the calls we receive are when the IM4406 is at the point of failure and nothing is really working except the clock.

 

 (Pink arrows point to voltage regulators)

The power supply in the IM4406 is a modern design and it uses components to create many different electrical voltages, which are used to power different parts of the IM4406 master station.

(Aluminum Heat Sink for the Power Module)

 

Most of these power regulators are mounted to the massive aluminum heat sink on the back of the power module. However there is one regulator that is not mounted this way; it is just mounted flat against the circuit board.

(voltage regulator removed, dark area on circuit board caused by excessive heat) 

Over time, and while the values of other supporting components drift, this regulator will start to run hot. Over time it will continue to get hotter and hotter, and since the regulator is not mounted on the heat sink, the excessive heat it generates has no place to go and the regulator fails.

I have seen units where the regulator could be pulled off the circuit board with your fingers because the solder connections had failed due to the long term exposure of the heat. When this regulator fails, the IM4406 stops working.

Luckily, repairing this problem is very straight forward, but for a long lasting repair more than just a new regulator will be needed. All of the supporting components in the power supply circuit should be changed and the primary capacitors should be checked and replaced as needed.

 

There is also a modification that should be done to improve how the regulator is mounted in the power module. This modification is based on a change that was made in the final version of the IMA4406.

 

An aluminum bracket needs to be fabricated and the regulator needs to be mounted to one end of the bracket. The other end of the bracket is fastened to the metal covering of the large aluminum heat sink. This gives the heat that the regulator generates a path to the large heat sink. This modification keeps the regulator operating temperature well within the normal range for this component.

 

These types of voltage regulators are available with different power output ratings, for different applications. We use a replacement regulator which has a higher rating than the original component and it also has a different case style, which works better to transfer the heat away from the component.

The original regulator has an all plastic case and the replacement has a case with a metal backing plate to aid in the transfer of the heat. Since the metal backing plate is conductive, it is necessary to use a insulating transistor mounting kit when attaching the regulator to the bracket. Without this kit the regulator will fail quickly.

Along with the regulator replacement and bracket modification, there are 6 capacitors and 4 diodes that will also need to be replaced.

 

The power supply circuit for the IM4406 includes 7 larger capacitors. These have not been a big problem on too many IM4406 Master Stations, however there have been a few units in which these capacitors have failed. It's a good idea to check these capacitors with an ESR meter and evaluate their condition. If they show any signs of increased resistance, they should be replaced.

 

When the repair of the IM4406 is completed, the power supply circuit should last longer than the original design. The IM4406 may be the high point of NuTone Music Intercom System design and it certainly is worth keeping it in good working condition.